6FC5357-0BB35-0AA0
SIEMENS SINUMERIK CNC
Country of origin : Germany . Siemens spare part .
| Article Number (Market Facing Number) | 6FC5357-0BB35-0AA0 |
| Product Description | SINUMERIK 840D/DE CNC-HARDWARE NCU 573.5, 933 MHZ, 64 MB WITHOUT SYSTEM SOFTWARE MEMORY: NC 3 MB, PLC 128 KB PREPARED FOR PROFIBUS DP, |
| product name | SINUMERIK 840D powerline NCU 573.5 | |
| unit series | SINUMERIK 840D | |
| processor | Pentium III | |
| processor / clock frequency | 933000000 Hz | |
| user memory | 64 MB DRAM, 8 MB SRAM | |
| SIMATIC S7 – integrated | PLC 317-2 DP | |
| dimension / width | 50 mm | |
| dimension / height | 316 mm | |
| dimension / depth | 207 mm | |
| weight / approx. | 1.05 kg | |
| Input voltage | via SIMODRIVE device bus | |
| power loss | 40 W | |
| mounting position | vertical | |
| heat dissipation | Open-circuit ventilation | |
| licence | CE, cULus | |
| Umgebungsbedingungen | ||
| degree of protection | IP20 (with NCU box) | |
| degree of protection / front side | IP20 | |
| degree of protection / reverse side | IP00 | |
| humidity rating | Class 3K5 condensation and icing excluded. Low air temperature 0 °C, (+32 °F) | |
| relative humidity / operation | < 95% for 1h, annual average< 65% | |
| relative humidity / storage | 10 … 95% | |
| relative humidity / conveyance | 10 … 95% | |
| relative humidity / test standard | DIN EN 60068-2-1, 60068-2-2, 60068-2-14, 60068-2-30 | |
| ambient temperature / during operation / min. | 0 °C, | |
| ambient temperature / during operation / max. | 55 °C, | |
| ambient temperature / when stored / min. | -20 °C, | |
| ambient temperature / when stored / max. | 60 °C, | |
| ambient temperature / when transported / min. | -20 °C, | |
| ambient temperature / when transported / max. | 60 °C, | |
| temperature / temperature change / max. | 12 °C,/h | |
| temperature / temperature change / max. / operation | 10 °C,/h | |
| temperature / temperature change / max. / conveyance | 18 °C,/h | |
| environmental conditions / mechanical environmental conditions / vibration / operation | 10-58 Hz: 0,075 mm, 59-500 Hz: 9,8 m/s2 | |
| environmental conditions / mechanical environmental conditions / vibration / conveyance | 5-9 HZ: 3,5 mm, 9-200 Hz: 9,8 m/s2 | |
| environmental conditions / mechanical environmental conditions / vibration / test standard | DIN EN 60068-2-6 | |
| environmental conditions / mechanical environmental conditions / shock resistance / operation | 50 m/s2, 30 ms, 18 shocks | |
| environmental conditions / mechanical environmental conditions / shock resistance / conveyance | 300 m/s2, 6 ms, 18 shocks | |
| environmental conditions / mechanical environmental conditions / shock resistance / Test Standard | DIN EN 60068-2-27 | |
| Schnittstellen | ||
| interfaces | OPI/MPI/S7-300/PROFIBUS-DP/Drive bus/Device bus/2 probes/2 handwheels/4 inputs/outputs/Link module | |
| interfaces / PC card slot | PCMCIA | |
| interfaces / PROFIBUS-DP/MPI | MPI/DP RS 485 | |
| interfaces / PROFIBUS-DP | 1,5Mbaud | |
| interfaces / handwheel | 2 handwheels via cable distributor | |
| interfaces / I/Os | Via cable distributor | |