Variable speed drive, Altivar Machine ATV320, 0.37 kW, 380…500 V, 3 phases, compact
Range of Product | Altivar Machine ATV320 |
---|---|
Product or Component Type | Variable speed drive |
Product Specific Application | Complex machines |
Variant | Standard version |
Format of the drive | Compact |
Mounting Mode | Wall mount |
communication port protocol | Modbus serial CANopen |
option card | Communication module, CANopen communication module, EtherCAT communication module, Profibus DP V1 communication module, PROFINET communication module, Ethernet Powerlink communication module, EtherNet/IP communication module, DeviceNet |
[Us] rated supply voltage | 380…500 V – 15…10 % |
Nominal output current | 1.5 A |
motor power kW | 0.37 kW heavy duty |
EMC filter | Class C2 EMC filter integrated |
IP degree of protection | IP20 |
Discrete input number | 7 |
---|---|
discrete input type | STO safe torque off, 24 V DC1.5 kOhm DI1…DI6 logic inputs, 24 V DC 30 V) DI5 programmable as pulse input 0…30 kHz, 24 V DC 30 V) |
Discrete input logic | Positive logic (source) Negative logic (sink) |
Discrete output number | 3 |
discrete output type | Open collector DQ+ 0…1 kHz 30 V DC 100 mA Open collector DQ- 0…1 kHz 30 V DC 100 mA |
Analogue input number | 3 |
analogue input type | AI1 voltage 0…10 V DC 30 kOhm 10 bits AI2 bipolar differential voltage +/- 10 V DC 30 kOhm 10 bits AI3 current 0…20 mA (or 4-20 mA, x-20 mA, 20-x mA or other patterns by configuration) 250 Ohm 10 bits |
Analogue output number | 1 |
Operating position | Vertical +/- 10 degree |
---|---|
Product Certifications | CE ATEX NOM GOST EAC RCM KC |
marking | CE ATEX UL CSA EAC RCM |
Standards | EN/IEC 61800-5-1 |
electromagnetic compatibility | Electrostatic discharge immunity test level 3 IEC 61000-4-2 Radiated radio-frequency electromagnetic field immunity test level 3 IEC 61000-4-3 Electrical fast transient/burst immunity test level 4 IEC 61000-4-4 1.2/50 µs – 8/20 µs surge immunity test level 3 IEC 61000-4-5 Conducted radio-frequency immunity test level 3 IEC 61000-4-6 Voltage dips and interruptions immunity test IEC 61000-4-11 |
Environmental class (during operation) | Class 3C3 according to IEC 60721-3-3 Class 3S2 according to IEC 60721-3-3 |
Maximum acceleration under shock impact (during operation) | 150 m/s² at 11 ms |
Maximum acceleration under vibrational stress (during operation) | 10 m/s² at 13…200 Hz |
Maximum deflection under vibratory load (during operation) | 1.5 mm at 2…13 Hz |
Permitted relative humidity (during operation) | Class 3K5 according to EN 60721-3 |
Volume of cooling air | 4755.18 Gal/hr(US) (18.0 m3/h) |
Overvoltage category | III |
Regulation loop | Adjustable PID regulator |
speed accuracy | +/- 10 % of nominal slip 0.2 Tn to Tn |
Pollution degree | 2 |
Ambient air transport temperature | -13…158 °F (-25…70 °C) |
ambient air temperature for operation | 14…122 °F (-10…50 °C) without derating 122…140 °F (50…60 °C) with derating factor |
Ambient Air Temperature for Storage | -13…158 °F (-25…70 °C) |
Category | 22152-ATV320/ATV312/ATV32 (.25 THRU 7.5HP) |
---|---|
Discount Schedule | CP4B |
GTIN | 3606480966712 |
Returnability | Yes |
Country of origin | ID |