6SE7032-6EG60 | 6SE70326EG60 SIMOVERT MD Converter unit 3AC 380-480V, 132KW

SIEMENS
Specification
Brand/Manufacturer: SIEMENS

Status: Available

Series: SIMOVERT VC

Place of Origin: Made in Germany

Alternate PN: 6SE7032-6EG60

Inquire for best price

Buy SIEMENS SIMOVERT VC 6SE7032-6EG60 at ABBPLCs.com, Best price and Big Stock.

6SE7032-6EG60 | 6SE70326EG60

SIMOVERT MD Converter unit 3AC 380-480V, 132KW

SIMOVERT MASTERDRIVES VECTOR CONTROL CONVERTER CHASSIS UNIT, IP00 3 380-480V AC, 50/60HZ, 260 A NOM. POWER RATINGS: 132KW DOCUMENTATION ON CD

Product Series: SIMOVERT MASTERDRIVES VC (Vector Control) Frequency Converter

image

1. Basic Electrical Specifications

Parameter Value
Model Number 6SE7032-6EG60
Device Type Chassis-mounted vector control converter
Rated Power 132 kW (200 HP)
Rated Output Current 260 A (nominal)
Input Voltage 3-phase AC, 380–480 V
Input Frequency 50/60 Hz (auto-adapting)
Output Voltage 0–input voltage (3-phase AC)
Output Frequency Range 0–300 Hz (standard)
Control Modes V/f control, Sensorless vector control, Closed-loop vector control (with encoder)
DC Link Voltage 510–650 V DC (nominal)
Cooling Method Forced air cooling (standard); water-cooled version: 6SE7032-6EG60-1AA1
Protection Degree IP00 (cabinet installation)

2. Performance & Overload Data

Parameter Value
Overload Capacity 150% of Iₙ for 60 sec (every 300 sec)
Torque Accuracy Closed-loop vector: ±2% of rated torque
Speed Stability Closed-loop (encoder): ±0.01% of max. speed
Switching Frequency 2–16 kHz (adjustable)
Dynamic Response Fast current/torque control (ms-level)

3. Environmental Ratings

Parameter Value
Operating Temperature 0–40 °C (no derating); up to 50 °C (derated)
Storage Temperature -25–+70 °C
Relative Humidity 5–80% RH (non-condensing)
Max. Operating Altitude ≤1000 m (no derating); derated above 1000 m
Vibration Resistance IEC 60068-2-6: 1 g (10–58 Hz)
Shock Resistance IEC 60068-2-27: 15 g (11 ms)

4. Interfaces & Connections

Interface Details
Analog Inputs 2 channels (0–10 V, ±10 V, 0–20 mA, 4–20 mA)
Analog Outputs 2 channels (0–10 V, 0–20 mA)
Digital Inputs 6–8 optically isolated inputs (24 V DC)
Digital Outputs 3–4 relay outputs (30 V DC / 250 V AC, 5 A)
Encoder Interface Supports TTL/HTL encoders (sin/cos optional)
Communication Ports – Serial: RS232/RS485

– Optional: PROFIBUS-DP, DeviceNet, Modbus, CANopen

5. Protection & Diagnostics

Function Description
Overcurrent Protection IGBT short-circuit, output short-circuit protection
Overvoltage Protection DC link overvoltage, input surge protection
Overtemperature Heat sink / IGBT overtemperature warning & trip
Phase Loss Input phase failure, output phase imbalance detection
Motor Protection PTC thermistor input, overload monitoring
Fault History Stores last 8–10 faults with time stamps

6. Physical & Mechanical Data

Parameter Value
Dimensions (W×H×D) Approx. 400 × 800 × 450 mm (chassis)
Weight Approx. 85–95 kg (air-cooled)
Mounting Vertical cabinet mounting
Cable Entry Top/bottom power terminals; front control terminals

 

parts photo album​

6SE7032-6EG60 | 6SE70326EG60 SIMOVERT MD Converter unit 3AC 380-480V, 132KW

Click edit button to change this text. Lorem ipsum dolor sit amet consectetur adipiscing elit dolor
Hot Sell

Click edit button to change this text. Lorem ipsum dolor sit amet, consectetur adipiscing elit. Ut elit tellus, luctus nec ullamcorper mattis, pulvinar dapibus leo.

Customer feedback
Rated 9 out of 10

People who viewed this item also viewed

Request for quotation and quote support