Product Overview: SIMOREG DC Master, single-quadrant (1Q) DC drive with B6C connection; 3-phase 690 V AC input, 830 V DC armature output, integrated 40 A field rectifier. Discontinued since 19.11.2020; recommended successor: 6RA8095-4KS22-0AA0 (2Q).
Option Codes Definition:
| Code | Description |
|---|---|
| D64 | Multilingual operating instructions (DE/EN/FR/ES/IT) on CD-ROM, including Drive‑Monitor software |
| G95 | PROFIBUS DP communication module CBP2, pre-installed in Slot E |
| K00 | Terminal extension module for additional I/O connections |
| K01 | Adapter module for Slot D and E, enabling module installation |
| K11 | Local Bus Adapter (LBA) for electronics box communication |
| S00 | Technological software package integrated in the basic unit |
1. Electrical Ratings (Armature)
| Parameter | Value | Notes |
|---|---|---|
| Input Voltage (3-phase AC) | 690 V AC | +10% / −15% tolerance; 50/60 Hz |
| Input Current (RMS) | 1658 A | At rated output, 690 V AC input |
| Output Voltage (DC) | 830 V DC | Max continuous; B6C bridge topology |
| Output Current (DC) | 2000 A (rated) | Continuous at 0–40 °C, separately cooled |
| US‑Rating Current (DC) | 1504 A | UL/CSA compliant rating for North America |
| Overload Current | 3000 A | 1.5 × In, for 60 s (cyclic duty) |
| Power Loss (Approx.) | 10.33 kW | At rated armature current |
| Typical System Power | Up to 1900 kW | At 830 V DC / 2000 A (DC motor) |
2. Electrical Ratings (Field Supply)
| Parameter | Value | Notes |
|---|---|---|
| Input Voltage | 460 V AC (1-phase) | Derived from main 690 V AC via internal transformer |
| Output Voltage (DC) | 375 V DC | Max continuous |
| Output Current (DC) | 40 A (rated) | Fully controllable rectifier |
| Control Type | Closed-loop current control | For separately excited DC motors |
3. Control Power Supply
| Parameter | Value | Notes |
|---|---|---|
| Voltage | 190–230 V AC (1-phase) | −25% / +15% tolerance |
| Current (Rated) | 2 A | 35% overload for 1 min |
| Frequency | 50/60 Hz | ±5% tolerance |
| Isolation | Reinforced isolation | Between control and power circuits |
4. Performance & Control
| Parameter | Value | Notes |
|---|---|---|
| Speed Control Stability (Encoder) | Δn = 0.006% of rated speed | Closed-loop with incremental encoder |
| Speed Control Stability (Tacho) | Δn = 0.1% of rated speed | Closed-loop with tachogenerator |
| Current Control Accuracy | ±0.5% of rated current | Static, closed-loop |
| Response Time (Current Loop) | < 1 ms | Typical, for fast torque control |
| Control Modes | Speed, torque, current, voltage | Parameterizable via OP1S or Drive‑Monitor |
| Auto-Optimization | Yes | For speed/current controllers and field control |
| I/O Interfaces | 4 analog inputs, 2 analog outputs, 8 digital inputs, 4 digital outputs | Expandable via K00 terminal extension |
| Communication | PROFIBUS DP V0/V1 | Via G95 (CBP2) module; baud rates up to 12 Mbps |
5. Mechanical & Environmental
| Parameter | Value | Notes |
|---|---|---|
| Protection Class | IP20 | Enclosure (electronics); power section IP00 |
| Ambient Temperature (Operation) | 0–40 °C | At full rating; derate 1% per °C above 40 °C (up to 50 °C) |
| Storage/Transport Temperature | −25 to +70 °C | No condensation |
| Humidity | 5–95% RH | Non-condensing; 40 °C at 90% RH |
| Altitude | ≤ 1000 m | Derate 1% per 100 m above 1000 m (up to 2000 m) |
| Cooling Method | Forced air (separately cooled) | Requires dedicated cooling system |
| Weight (Approx.) | 180–220 kg | Complete unit (power + control + options) |
| Dimensions (H×W×D, Approx.) | 2100 × 800 × 600 mm | Typical for large 6RA70 frames; verify with mechanical drawing |
6. Safety & Compliance
| Parameter | Value |
|---|---|
| Safety Standards | EN 60204-1, EN 61800-5-1, UL 508C |
| EMC Compliance | EN 61800-3 (Category C2), EN 55011 |
| Isolation Voltage | 4 kV AC (power/control), 2 kV AC (field/control) |
| Short-Circuit Protection | Yes (electronic + fast fuses) |
| Overvoltage Protection | Yes (MOV + active clamping) |
| Undervoltage Protection | Yes (control power monitoring) |
| Thermal Protection | Yes (IGBT/thyristor + heatsink + motor PTC) |
7. Software & Diagnostics
| Feature | Details |
|---|---|
| Software Version | V2.0 (base); upgradable via flash EPROM |
| Diagnostics | Extensive fault logging, real-time status, oscilloscope function |
| Technological Functions (S00) | Sequencer, setpoint ramps, PID control, tension control, skip speeds |
| Parameter Storage | Non-volatile memory (EEPROM); backup/restore via Drive‑Monitor |
Key Notes
- Single-Quadrant Operation: Only motoring (forward direction); braking requires external resistors or a 4Q unit.
- US‑Rating: 1504 A is the UL/CSA compliant current for North American installations (lower than the 2000 A IEC rating).
- Successor: 6RA8095-4KS22-0AA0 is a 2-quadrant drive with similar ratings, improved efficiency, and modern communication (PROFINET optional).