Sales@aotewell.com

Whatsapp: +86-159 1408 1759

6SE7031-7HG60 | 6SE70317HG60 SIMOVERT MD Converter unit 3AC 660-690V, 160KW

SIEMENS
Specification
Brand/Manufacturer: SIEMENS

Status: Available

Series: SIMOVERT VC

Place of Origin: Made in Germany

Alternate PN: 6SE7031-7HG60

Inquire for best price

Buy SIEMENS SIMOVERT VC 6SE7031-7HG60 at ABBPLCs.com, Best price and Big Stock.

6SE7031-7HG60 | 6SE70317HG60

SIMOVERT MD Converter unit 3AC 660-690V, 160KW

SIMOVERT MASTERDRIVES VECTOR CONTROL CONVERTER CHASSIS UNIT, IP00 3 660-690V AC, 50/60HZ, 171 A NOM. POWER RATINGS: 160KW DOCUMENTATION ON CD

Product Series: SIMOVERT MASTERVERT VC (Vector Control) Frequency Converter

1. Basic Electrical Specifications

Parameter Value
Model Number 6SE7031-7HG60
Product Description Vector control converter chassis unit
Rated Power 160 kW (214 HP)
Rated Output Current 171 A (nominal)
Input Voltage 3-phase AC, 660–690 V
Input Frequency 50/60 Hz (auto-adapting)
Input Voltage Tolerance ±10% (594–759 V)
Output Voltage 0–input voltage (3-phase AC)
Output Frequency Range 0–300 Hz (standard)
DC Link Voltage 740–890 V DC (nominal)
Control Modes V/f control, Sensorless vector control, Closed-loop vector control (with encoder)
Cooling Method Forced air cooling
Protection Degree IP00 (cabinet installation)

2. Overload & Performance Data

Parameter Value
Overload Capacity 150% of In for 60 sec (every 300 sec)
Torque Accuracy Closed-loop vector: ±2% of rated torque
Speed Stability Closed-loop (encoder): ±0.01% of max. speed
Switching Frequency 2–16 kHz (adjustable)
Dynamic Response Fast current/torque control (ms-level)
Efficiency Approx. 97–98% (at rated load)

3. Environmental Ratings

Parameter Value
Operating Temperature 0–40 °C (no derating); 40–60 °C (derated)
Storage Temperature -25–+70 °C
Relative Humidity 5–95% RH (non-condensing)
Max. Operating Altitude ≤1000 m (no derating); derated above 1000 m
Vibration Resistance IEC 60068-2-6: 1 g (10–58 Hz)
Shock Resistance IEC 60068-2-27: 15 g (11 ms)

4. Interfaces & Connections

Interface Details
Analog Inputs 2 channels (0–10 V, ±10 V, 0–20 mA, 4–20 mA)
Analog Outputs 2 channels (0–10 V, 0–20 mA)
Digital Inputs 6–8 optically isolated inputs (24 V DC)
Digital Outputs 3–4 relay outputs (30 V DC / 250 V AC, 5 A)
Encoder Interface Supports TTL/HTL encoders (sin/cos optional)
Communication Ports – Serial: RS232/RS485

– Optional: PROFIBUS-DP, DeviceNet, Modbus, CANopen

5. Protection & Diagnostics

Function Description
Overcurrent Protection IGBT short-circuit, output short-circuit protection
Overvoltage Protection DC link overvoltage, input surge protection
Overtemperature Heat sink / IGBT overtemperature warning & trip
Phase Loss Input phase failure, output phase imbalance detection
Motor Protection PTC thermistor input, overload monitoring
Fault History Stores last 8–10 faults with time stamps

6. Physical & Mechanical Data

Parameter Value
Weight Approx. 75 kg
Mounting Vertical cabinet mounting
Dimensions (H×W×D) Standard chassis size (compatible with 6SE70 series)
Cable Entry Top/bottom power terminals; front control terminals

 

parts photo album​

6SE7031-7HG60 | 6SE70317HG60 SIMOVERT MD Converter unit 3AC 660-690V, 160KW

Click edit button to change this text. Lorem ipsum dolor sit amet consectetur adipiscing elit dolor
Hot Sell

Click edit button to change this text. Lorem ipsum dolor sit amet, consectetur adipiscing elit. Ut elit tellus, luctus nec ullamcorper mattis, pulvinar dapibus leo.

Customer feedback
Rated 9 out of 10

People who viewed this item also viewed

Request for quotation and quote support